Beckman AU480 Chemistry Analyzer, 2016
$25,800.00
This specific product is no longer available, however we may have other similar or identical products in stock. Please utilize our search function at the top of the page to check and confirm, or fill out the form below:
Analytical System: Fully Automated, Random Access Chemistry System With STAT Capability.
Analytical Principle: Spectrophotometry and Potentiometry
Analytical Types: Endpoint, Rate, Fixed Point and Indirect ISE
Analytical Methods: Colorimetry, Turbidimetry, Latex Agglutination, Homogeneous Eia, Indirect ISE
Simultaneously Processed Analytes: 60 Photometric Tests + 3 Ise, 120 Pre-Programmed Onboard Tests
Throughput: 400 Photometric Tests/Hour; Maximum of 800 With ISE
ISE Throughput: 200 samples/hr. Maximum tests/hr; 600 if ISE only
Sample Types: Serum, Plasma, Urine, Other
Sample Feeder: Racks with 10 Samples Each (Barcodes on Primary Tubes and On Racks); Capacity of 80 Samples; Continuous Loading
Sample Tubes: Primary and Secondary Tubes; Diameter From 11.5 to 16 mm; Height From 55 to 102 mmm, Nestled Micro Sample Cups
STAT Samples: Up to 22 Positions for STAT Samples via Cooled Turntable. Easy-To-Operate Interrupts Between Tests. Auto-Repeat Run Capability.
Sample Volume: 1โ25 ฮผl in 0.1 ฮผl steps (1-25 ฮผl for repeats)
Reagent Capacity: 76 Positions for (R1+R2, Detergent Position). Holds 15, 30 and 60ml bottles.
Reagent Storage: Refrigerated (4โ12ยฐC)
Reagent Volume: R1: 10โ250 ฮผl; R2: 10โ250 ฮผl (in 1 ฮผl increment)
Total Reaction Volume: 90-350 ฮผl
Reaction Cuvette: Permanent Glass Cuvettes
Reaction Time: Up to 8 minutes, 37.5 seconds
Reaction Incubation: 37ยฐC, dry bath
Photometry System: Direct Assay Through the Reaction Cuvette (0โ3.0 OD) Mono and Bichromatic Measurements Possible
Wavelength: 13 Different Wavelengths Between 340-800 nm
Calibration: Auto Calibration, Cooled Calibrator Positions; Master Calibration Established by Two-Dimensional Barcode
Quality Control: Auto QCD, cooled QC positions
Rerun: 1. Auto Rerun and Manual Rerun Available
2. Automatic Sample Increase, Decrease or Normal Repeat
3. Reflex Testing
Sample Pre-dilution: Dilution Ratio: Fixed to 3, 5, 10, 15, 20, 25, 50, 76 or 100
Test Requisition: Individual and Profile Test Requisition via Online, Mouse, Function Keys and Touch-Screen
Sample Integrity: Lipaemia, Haemolysis and Icterus Analysis. Sample Clot Detection and Probe Crash Protection.
Online: RS232C. Full Uni- and Bidirectional Communication Possible.
Software: Windows 7ยฎ
Data Storage: Sample Number 100,000 samples. Reaction Data 200,000 tests
Dimensions (W x H x D): ANL; 1,450 x 1,205 x 760
Weight: 960 lbs
Power Supply: 100-240v; 60 Hz/ <3.5kVA
Water system included.