312-761-9396 Se habla español

312-761-9396 | Se Habla Espanol

 

Questions? Call 312-761-9396

Specifications

MakeBeckman
Year2016
Analytical SystemFully Automated, Random Access Chemistry System With STAT Capability.
Analytical PrincipleSpectrophotometry and Potentiometry
Analytical TypesEndpoint, Rate, Fixed Point and Indirect ISE
Analytical MethodsColorimetry, Turbidimetry, Latex Agglutination, Homogeneous Eia, Indirect ISE
Simultaneously Processed Analytes60 Photometric Tests + 3 Ise, 120 Pre-Programmed Onboard Tests
Throughput400 Photometric Tests/Hour; Maximum of 800 With ISE
ISE Throughput200 samples/hr. Maximum tests/hr; 600 if ISE only
Sample TypesSerum, Plasma, Urine, Other
Sample FeederRacks with 10 Samples Each (Barcodes on Primary Tubes and On Racks); Capacity of 80 Samples; Continuous Loading
Sample TubesPrimary and Secondary Tubes; Diameter From 11.5 to 16 mm; Height From 55 to 102 mmm, Nestled Micro Sample Cups
STAT SamplesUp to 22 Positions for STAT Samples via Cooled Turntable. Easy-To-Operate Interrupts Between Tests. Auto-Repeat Run Capability.
Sample Volume1–25 μl in 0.1 μl steps (1-25 μl for repeats)
Reagent Capacity76 Positions for (R1+R2, Detergent Position). Holds 15, 30 and 60ml bottles.
Reagent StorageRefrigerated (4–12°C)
Reagent VolumeR1: 10–250 μl; R2: 10–250 μl (in 1 μl increment)
Total Reaction Volume90-350 μl
Reaction CuvettePermanent Glass Cuvettes
Reaction TimeUp to 8 minutes, 37.5 seconds
Reaction Incubation37°C, dry bath
Photometry SystemDirect Assay Through the Reaction Cuvette (0–3.0 OD) Mono and Bichromatic Measurements Possible
Wavelength13 Different Wavelengths Between 340-800 nm
CalibrationAuto Calibration, Cooled Calibrator Positions; Master Calibration Established by Two-Dimensional Barcode
Quality ControlAuto QCD, cooled QC positions
Rerun1. Auto Rerun and Manual Rerun Available
Sample Pre-dilutionDilution Ratio: Fixed to 3, 5, 10, 15, 20, 25, 50, 76 or 100
Test RequisitionIndividual and Profile Test Requisition via Online, Mouse, Function Keys and Touch-Screen
Sample IntegrityLipaemia, Haemolysis and Icterus Analysis. Sample Clot Detection and Probe Crash Protection.
OnlineRS232C. Full Uni- and Bidirectional Communication Possible.
SoftwareWindows 7®
Data StorageSample Number 100,000 samples. Reaction Data 200,000 tests
Dimensions (W x H x D)ANL; 1,450 x 1,205 x 760
Weight960 lbs
Power Supply100-240v; 60 Hz/

2. Automatic Sample Increase, Decrease or Normal Repeat
3. Reflex Testing

BP
7327603780

Sold

Beckman AU480 Chemistry Analyzer, 2016

This product is no longer available.

Looking for one like it? Tell us what you need, and we’ll search for a similar option.