312-761-9396 | Se Habla Espanol

 

AM
44206603175

Thermotron SE-300-4-4 Environmental Test Chamber, 2014

$9,900.00

This specific product is no longer available, however we may have other similar or identical products in stock. Please utilize our search function at the top of the page to check and confirm, or fill out the form below:

Electrical
Supply: 230 V, 3-phase, 60 Hz (230-3-60)
Maximum Load: 55.2 A
Recommended Service: 60 A
Enclosure Type: 1

Motors & Loads
Largest Motor: 4 HP — 10.5 A
Largest Heater Load: 8 kW — 20.1 A
Other Loads: 24.6 A
Total (as shown): (Maximum Load indicated on nameplate: 55.2 A)

Short-Circuit / Wiring
Short Circuit Current Rating: 5 kA RMS symmetrical
Voltage Rating for Short-Circuit Spec: 250 V max.
Wiring Schematic: E45645-1

Refrigeration & Standby
Refrigerant (primary): R508B — 2.0 lbs
Alternate / additional refrigerant: R404A — 10.6 lbs
Standby Pressure: 120 PSIG